Single, Volume Controlled, up to 46 m3/h Series SM-SF/CSD
UTILITY
Water softeners are used in order to remove the total hardness of the water and to produce the so-called soft water. This is achieved by passing the water through ion-exchange resin bed, which exchanges the ions of Calcium and Magnesium with Sodium. When reached the pre-selected quantity of water, the system regenerated automatically, by means of salt solution (Sodium Chloride – brine).
The product water – free of hardness – does not cause salt scalings and the entire equipment that uses this water is thus protected.
COMMON APPLICATIONS
- Feed water for boilers or cooling towers.
- Total hardness reduction in water for general use running through distributing networks (industries, hotels, hospitals, buildings, residences etc).
- Any application which requires soft water.
ADVANTAGES
- Fully automated operation / possibility for manual regeneration according to the user’s will
- Automation operates on low voltage (12 VAC) for the personnel’s protection
- Minor pressure drop
- Minimum maintenance cost
- The resin tank is coated with high-density polyethylene, thus it has a high endurance against corrosion
- Electronic control panel
- Selection of the day and time of regeneration
- Brine tank fully equipped for the protection of the softener from the air
- Series SG is intended for softening of hot water up to 85 oC
The SM/CSD series designed for small water flow, up to 3,6 m3/h
Model | Operating Capacity m3*f°H |
Maximum flow m3/h |
Pressure loss bar |
---|---|---|---|
SM11/CSD | 70 | 1,8 | 0,8 |
SM21/CSD | 125 | 2,4 | 1,1 |
SM41/CSD | 210 | 3,0 | 1,2 |
SM61/CSD | 335 | 3,6 | 1,2 |
SM81/CSD | 600 | 3,6 | 1,2 |
SM101/CSD | 750 | 3,6 | 1,2 |
The SF/CSD series designed for higher water flow
Model | Operating Capacity m3*f°H |
Maximum flow m3/h |
Pressure loss bar |
---|---|---|---|
SF361/CSD | 750 | 10,8 | 2 |
SF601/CSD | 1100 | 12,6 | 2 |
SF801/CSD | 1500 | 12,6 | 2 |
SF1201/CSD | 2250 | 13,2 | 2 |
SF1801/CSD | 3400 | 13,2 | 2 |
SF2001/CSD | 4900 | 13,2 | 2 |
The SFH/CSD series designed for even higher water flow, with external galvanized steel piping
Model | Operating Capacity m3*f°H |
Maximum flow m3/h |
Pressure loss bar |
---|---|---|---|
SFH601/CSD | 1100 | 20,4 | 2 |
SFH1201/CSD | 2250 | 36 | 2 |
SFH1801/CSD | 3400 | 46 | 2 |
SFH2001/CSD | 4900 | 46 | 2 |
The SMH/CSD series has the same design against SFH/CSD, but external piping constructed from PVC
Model | Operating Capacity m3*f°H |
Maximum flow m3/h |
Pressure loss bar |
---|---|---|---|
SMH361/CSD | 750 | 8 | 1,8 |
SMH601/CSD | 1100 | 10 | 1,8 |
SMH901/CSD | 1800 | 16 | 1,8 |
SMH1201/CSD | 2400 | 18 | 1,8 |
SMH1801/CSD | 3670 | 20 | 1,8 |
SMH2001/CSD | 5200 | 18 | 1,8 |
Finally series SML/ETP4 has the same design against SMH/ETP4, but even higher water flow
Model | Operating Capacity m3*f°H |
Maximum flow m3/h |
Pressure loss bar |
---|---|---|---|
SML1201/CSD | 2400 | 30 | 1,8 |
SML1801/CSD | 3670 | 40 | 1,8 |
SML2001/CSD | 5200 | 32 | 1,8 |